<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>hexs Archives - WeBBusterZ Engineering</title>
	<atom:link href="https://www.webbusterz.net/tag/hexs/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.webbusterz.net/tag/hexs/</link>
	<description>Engineering Software Solutions</description>
	<lastBuildDate>Mon, 04 May 2026 16:48:24 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.webbusterz.net/wp-content/uploads/2017/03/cropped-wbzlogo-300x141-32x32.png</url>
	<title>hexs Archives - WeBBusterZ Engineering</title>
	<link>https://www.webbusterz.net/tag/hexs/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HExS version history</title>
		<link>https://www.webbusterz.net/hexs-version-history/</link>
		
		<dc:creator><![CDATA[webbusterz]]></dc:creator>
		<pubDate>Fri, 04 Mar 2022 16:47:36 +0000</pubDate>
				<category><![CDATA[Software version history]]></category>
		<category><![CDATA[hexs]]></category>
		<guid isPermaLink="false">http://www.webbusterz.net/?p=1217</guid>

					<description><![CDATA[<p>Heat exchanger suite (HExS) version history HExS &#8211; 6.0.0.0 COMMON FOR ALL SUB MODULES &#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8211; ACHex Updated&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;-ACHEX &#8211; v3.0.0.0 CnD Updated&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;-CnD &#8211; v1.9.0.0 DHex Updated&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;-DHex &#8211; v6.0.0.0 HCHex Updated&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;HCHex &#8211; v4.0.0.0 KRD Updated&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8211;KRD V6.0.0.0 PHex Updated&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8211;PHex &#8211; v11.0.0.0 S&#38;THex Updated&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;-S&#38;THex &#8211; v6.0.0.0 VTD Updated&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8211;VTD &#8211; v4.0.0.0 HExS – 5.0.0.0 S&#38;THex Updated——————-S&#38;THex – v5.1.0.1 S&#38;THex – v5.1.0.0 HCHex Updated——————-HCHex – v3.0.0.2 HCHex – v3.0.0.1 CnD Updated———————CnD&#8230; </p>
<p>The post <a href="https://www.webbusterz.net/hexs-version-history/">HExS version history</a> appeared first on <a href="https://www.webbusterz.net">WeBBusterZ Engineering</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>Heat exchanger suite (HExS) version history </p>



<h2 class="wp-block-heading">HExS &#8211; 6.0.0.0</h2>



<ul class="wp-block-list">
<li>Added license tools to allow license removal for users with an active maintenance plan.</li>



<li>Added Download button in the Check for Updates window to enable automated updates to the latest version for users with an active maintenance plan.</li>
</ul>



<p><strong>COMMON FOR ALL SUB MODULES &#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8211;</strong></p>



<ul class="wp-block-list">
<li>Added/Update error log viewer for all sub modules. The log now issue messages that includes the following types:<br>ERROR: This type of messages is used for errors in input or results, the software will stop until errors are fixed by the user<br>WARNING: This type of message is used for warning when parameters are exceeded, the software will continue buy some results may be invalid<br>MESSAGE: This type of message is used for general software informative messages<br>INFO: This type of message is used to provide additional information and guidance during operation</li>
</ul>



<p><strong>ACHex Updated&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;-</strong><br>ACHEX &#8211; v3.0.0.0</p>



<ul class="wp-block-list">
<li>Error log view enhancement as described above</li>
</ul>



<p><strong>CnD Updated&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;-</strong><br>CnD &#8211; v1.9.0.0</p>



<ul class="wp-block-list">
<li>Added option to specify coolant-side heat transfer coefficient<br>Users can now override the calculated coolant-side heat transfer coefficient with a user-defined value.<br>This allows greater flexibility when modelling cases where standard correlations may not be applicable, including non-standard coolant conditions.<br>The specified value is used in the overall heat transfer coefficient calculation, while all other calculations remain unchanged.</li>
</ul>



<p><strong>DHex Updated&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;-</strong><br>DHex &#8211; v6.0.0.0</p>



<ul class="wp-block-list">
<li>Minor optimisation to code</li>



<li>Error log view enhancement as described above</li>
</ul>



<p><strong>HCHex Updated&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;</strong><br>HCHex &#8211; v4.0.0.0</p>



<ul class="wp-block-list">
<li>Bug Fix during loading file =&gt; Prandtl number on shell and tube sides now recalculated on every load if checked for calculation</li>



<li>Added calculations<br>|_ Overall heat transfer coefficient (Clean)<br>|_ Overdesign<br>|_ Safety Factor<br>|_ Area calculation renamed to &#8220;Required Area (based on fouled U)&#8221;<br>|_ Available Area (coil external surface)</li>



<li>Updated calculation summary</li>



<li>Error log view enhancement as described aboveinclude the following types:</li>
</ul>



<p><strong>KRD Updated&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8211;</strong><br>KRD V6.0.0.0</p>



<ul class="wp-block-list">
<li>Major interface update</li>



<li>Error log view enhancement as described above</li>



<li>Bug fix &#8211; detected during saved file loading</li>
</ul>



<p><strong>PHex Updated&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8211;</strong><br>PHex &#8211; v11.0.0.0</p>



<ul class="wp-block-list">
<li>Error log view enhancement as described above</li>



<li>Input consistancy check implemented to warn users when incorrect decimal point format is used<br><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2728.png" alt="✨" class="wp-smiley" style="height: 1em; max-height: 1em;" /> New Feature: Advanced User-Defined Correlations (Nusselt &amp; Fanning Friction Factor)</li>



<li>Added support for advanced user-defined Nusselt number correlations using custom mathematical expressions.</li>



<li>Introduced a new Advanced Correlations interface, allowing users to define correlations based on:<br>|- Reynolds number (Re)<br>|- Prandtl number (Pr)<br>|- Fluid viscosity (μ)<br>|- Wall viscosity (μw)</li>



<li>Added support for custom Fanning friction factor correlations for channel pressure drop calculations.<br>|- These can be enabled via the Advanced Options tab.<br>|- Allows fine control of pressure drop predictions for specialised cases.</li>



<li>Implemented validity range checking for all advanced correlations:<br>|- Users can define Re and Pr limits.<br>|- Warnings are issued when calculations fall outside these limits.</li>



<li>Added automatic fallback to software correlations when:<br>|- Selected advanced correlation is outside its validity range<br>|- Optional behaviour controlled via checkbox</li>



<li>Improved correlation handling:<br>|- Separation between standard, user, and advanced correlations<br>|- Ensures backward compatibility with existing projects</li>



<li>Exit Pressure calculation on Hot and Cold sides</li>



<li>Added support for user-defined heat transfer coefficients on both hot and cold sides.<br>This allows advanced users to override internal correlations and apply custom or experimentally<br>derived values where required.</li>



<li>Added an alternative thermal design method allowing a user-defined margin to be applied to the<br>clean overall heat transfer coefficient when fouling factors are not used.<br>The resulting design coefficient is then used in duty and area calculations.</li>
</ul>



<p><strong>S&amp;THex Updated&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;-</strong><br>S&amp;THex &#8211; v6.0.0.0</p>



<ul class="wp-block-list">
<li>Added alternative geometric bundle diameter estimation for non-standard tube pitch configurations.<br>The default standard tube-count correlation method remains unchanged.</li>



<li>Added license tools to allow license removal for users with an active maintenance plan.</li>



<li>Added Download button in the Check for Updates window to enable automated updates to the latest version for users with an active maintenance plan.</li>



<li>Fixed issue when reading settings file at the start of design mode.<br><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f527.png" alt="🔧" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Shell-Side Baffle Calculation Enhancements</li>



<li>Added support for Disc &amp; Doughnut shell-side calculation modes:<br>|- Approximate<br>|- Geometry</li>



<li>Added support for Orifice shell-side calculation modes:<br>|- Approximate<br>|- Open Area Based</li>



<li>Added support for Segmental and Strip shell-side calculation modes:<br>|- Approximate (user-defined correction factor)<br>|- Strip Corrected (sealing-strip-based bypass correction)</li>



<li>Added Number of Sealing Strip Pairs input for Segmental and Strip baffle type.</li>



<li>Added optional automatic estimation of sealing strip pairs based on effective tube rows crossed.<br><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2699.png" alt="⚙" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Calculation Improvements</li>



<li>Implemented mode-dependent shell-side flow area calculations (Step 9) for advanced baffle types.</li>



<li>Implemented mode-dependent shell-side pressure-drop calculations for:<br>|- Calculation Method 1 (Frank-based)<br>|- Calculation Method 2 (Kern-based)</li>



<li>Introduced geometry-based and open-area-based correction models for Disc &amp; Doughnut and Orifice baffles.</li>



<li>Introduced Bell–Delaware-inspired bypass correction for Segmental and Strip baffles using sealing strip ratio.<br><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/26a0.png" alt="⚠" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Validation &amp; Usability Enhancements</li>



<li>Added validation and warnings for:<br>|- Disc &amp; Doughnut geometry inputs<br>|- Orifice open area inputs<br>|- Segmental and Strip sealing strip configuration</li>



<li>Added intelligent guidance messages for:<br>|- sealing strip estimation<br>|- geometry ranges<br>|- applicability of baffle cut</li>



<li>Added New Feature: Advanced User-Defined Nusselt Correlations<br>This feature provides advanced flexibility for expert users while maintaining<br>compatibility with existing correlation workflows.<br>|- Added a new Advanced Correlation Builder for defining custom Nusselt correlations<br>|- Supports full mathematical expressions using:<br>-&gt; Re, Pr, μ, μw<br>-&gt; Standard operators and functions (log, ln, sqrt, power, exp)<br>|- Includes:<br>-&gt; Expression validation<br>-&gt; Built-in testing tool<br>-&gt; Optional applicability limits (Re, Pr)<br>-&gt; Reference field for documentation<br>|- Advanced correlations are stored separately and accessed via a dedicated tab<br>|- Automatic calculation of Nusselt number upon selection<br>|- Warnings are logged when operating outside defined correlation limits<br>|- Improved stability and consistency of selection behavior across all correlation types</li>
</ul>



<p><strong>VTD Updated&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8211;</strong><br>VTD &#8211; v4.0.0.0</p>



<ul class="wp-block-list">
<li>Error log view enhancement as described above</li>
</ul>



<h2 class="wp-block-heading">HExS – 5.0.0.0</h2>



<p><strong>S&amp;THex Updated——————-</strong><br>S&amp;THex – v5.1.0.1</p>



<ul class="wp-block-list">
<li>Internal code refining for Heat Exchanger Suite (HExS) publish automation</li>
</ul>



<p>S&amp;THex – v5.1.0.0</p>



<ul class="wp-block-list">
<li>Bug fix to address saving and loading of multi-case scenario simulation</li>



<li>bug fix in FSerializor.dll that affects saving and loading cultures like South Korea.</li>



<li>Enhanced material thermal conductivities database and added more material thermal conductvities.</li>
</ul>



<p><strong>HCHex Updated——————-</strong><br>HCHex – v3.0.0.2</p>



<ul class="wp-block-list">
<li>Internal code refining for Heat Exchanger Suite (HExS) publish automation</li>



<li>Added Water and Steam Properties Tool</li>
</ul>



<p>HCHex – v3.0.0.1</p>



<ul class="wp-block-list">
<li>Update to saving and loading feature to address a bug in loading files</li>



<li>Updated FSerializor.dll with new load and save functions to fix issues with saving files from different cultures locations i.e South Korea</li>



<li>Expand the material thermal conductivity database</li>



<li>Added physical properties PProps internal database containing 500 fluids</li>



<li>Added new setting to check for software updates on start</li>
</ul>



<p><strong>CnD Updated———————</strong><br>CnD – v1.8.0.1</p>



<ul class="wp-block-list">
<li>Enhanced material thermal conductivities database and added more material thermal conductivities.</li>
</ul>



<p>CnD – v1.8.0.0</p>



<ul class="wp-block-list">
<li>Expand the material thermal conductivity database</li>



<li>Added internal physical properties database containing 500 fluids</li>



<li>Support Calculation for outlet pressures for shell and tube sides</li>



<li>Enhanced the calculation tracker to include differences that appear (added/removed/changed),<br>the change difference is also calculated and displayed with change indicator.</li>



<li>Option to set the number of decimals added for results number formatting</li>



<li>Option to allow the input of Heat Duty</li>



<li>Add the ability to calculate the hot side vapor temperature and condensate outlet temperature &lt;- Activated based on scenarios below:<br>if the vapor is superheated the inlet temperature of vapor can be calculated providing all input variables of calculation are entered<br>if the condensate is subcooled the outlet temperature of condensate can be calculated providing all input variables of calculation are entered</li>



<li>Added new setting to check for software updates on start</li>



<li>Update error log viewer, the software will now issue messages in the error log that<br>include the following types:<br>ERROR: This type of messages is used for errors in input or results, the software will stop until errors are fixed by the user<br>WARNING: This type of message is used for warning when parameters are exceeded, the software will continue buy some results may be invalid<br>MESSAGE: This type of message is used for general software informative messages<br>INFO: This type of message is used to provide additional information and guidance during operation<br>UPDATE: This message is issues if a new version of the software is detected</li>



<li>Interface update – Hide and View error log and button panels</li>



<li>Interface update – Project Inputs screen</li>



<li>Interface update – Enhanced results display</li>



<li>Enhance design summary report</li>



<li>update to report viewer internal library</li>



<li>bug fixes and code optimisation</li>
</ul>



<p><strong>ACHex Updated——————-</strong><br>ACHEX – v2.2.0.0</p>



<ul class="wp-block-list">
<li>Enhanced material thermal conductivities database and added more material thermal conductivities.</li>



<li>Internal code refining for Heat Exchanger Suite (HExS) publish automation</li>



<li>Added physical properties PProps internal database containing 500 fluids</li>



<li>Added new setting to check for software updates on start</li>
</ul>



<p><strong>DHex Updated———————</strong><br>DHex – v5.0.0.0</p>



<ul class="wp-block-list">
<li>Internal code refining for Heat Exchanger Suite (HExS) publish automation</li>



<li>Enhanced material thermal conductivities database and added more material thermal conductivities.</li>



<li>Added new setting to check for software updates on start</li>



<li>Added physical properties PProps internal database containing 500 fluids</li>
</ul>



<p><strong>KRD Updated———————-</strong><br>KRD – v5.0.0.0</p>



<ul class="wp-block-list">
<li>Enhanced material thermal conductivities database and added more material thermal conductivities.</li>



<li>Internal code refining for Heat Exchanger Suite (HExS) publish automation</li>



<li>Added new setting to check for software updates on start</li>



<li>Added physical properties PProps internal database containing 500 fluids</li>
</ul>



<p><strong>PHex Updated———————-</strong><br>PHex – v10.0.0.0</p>



<ul class="wp-block-list">
<li>Internal code refining for Heat Exchanger Suite (HExS) publish automation</li>



<li>Enhanced material thermal conductivities database and added more material thermal conductivities.</li>



<li>Added water and Steam Properties</li>



<li>Added new setting to check for software updates on start</li>



<li>Added physical properties PProps internal database containing 500 fluids</li>
</ul>



<p><strong>VTD Updated———————–</strong><br>VTD – v3.0.0.0</p>



<ul class="wp-block-list">
<li>Internal code refining for Heat Exchanger Suite (HExS) publish automation</li>



<li>Enhanced material thermal conductivities database and added more material thermal conductvities.</li>



<li>Added new setting to check for software updates on start</li>



<li>Added physical properties PProps internal database containing 500 fluids</li>
</ul>



<h2 class="wp-block-heading">HExS &#8211; 4.0.0.0</h2>



<ul class="wp-block-list">
<li>PProps physical properties tool update<br>|_ Added support to estimation thermal conductivity<br>|_ Added phase detection</li>



<li>Added check for updates on startup &#8211; can be turned off from the check for updates screen</li>
</ul>



<p>Update to S&amp;THex</p>



<ul class="wp-block-list">
<li>Enhance mechanical calculations<br>|_ Added Joint weld efficiency input for nozzles design steps mechanical section<br>|_ Added Error checks for nozzle thickness calculations</li>



<li>Added and approximation fall back method to calculated the bundle diameter</li>



<li>Added Calculation of fluid outlet pressure for both Shell side and Tube side</li>



<li>Added support to no baffles scenario calculations</li>



<li>Added new graphics for drawing summary and improved design summary</li>



<li>Added a setting to allow users the ability to select the exchanger for the drawing summary representation</li>



<li>Added new setting to check for software updates on start</li>



<li>Added PProps Physical Properties containing estimation for 500 fluids</li>
</ul>



<p>Update to DHex<br>+Bug affecting the export to datasheet function has been identified and fixed</p>



<p>Update to PHex<br>+Bug affecting the export to datasheet function has been identified and fixed</p>



<h2 class="wp-block-heading">HExS – 3.0.0.0</h2>



<p>Software licensing on new activation server<br>Update to ACHex</p>



<p>Minor update to results interface<br>Bug fix in export feature to .csv file<br>Update to HCHex</p>



<p>Bug fix affecting calculating unknown flow rate.<br>Added input validation error if the average diameter of helix is greater than the inside diameter of the outer cylinder<br>Added the ability to adjust the gap between the tube and the outer cylinder wall<br>Added the ability to adjust the gap between the tube and the core tube (for core tube models)<br>Update to CnD</p>



<p>Update report view for engineering datasheet generator</p>



<h2 class="wp-block-heading">HExS &#8211; 2.0.0.5</h2>



<p>Update to HCHex</p>



<ul class="wp-block-list">
<li>Added support for no core tube design</li>



<li>Allow the calculation of core tube diameter when Shell inside diameter is defined</li>



<li>Allow the calculation of Shell inside diameter when core tube diameter is defined</li>



<li>Allow the calculation of both core tube diameter and Shell inside diameter</li>



<li>Added new graphics</li>



<li>Updated summary screens</li>
</ul>



<h2 class="wp-block-heading">HExS &#8211; 2.0.0.4</h2>



<p>Update to DHex</p>



<ul class="wp-block-list">
<li>Maintenance release addressing<br>fixed bug to address failing to calculate the thermal capacity ratio<br>fixed bug to address failing to calculate the number of transfer unit<br>fixed bug to address failing to calculate pressure drop in annulus side</li>
</ul>



<p>Update to S&amp;THex</p>



<ul class="wp-block-list">
<li>Maintenance release<br>Added error check in physical properties import feature</li>
</ul>



<h2 class="wp-block-heading">HExS &#8211; 2.0.0.3</h2>



<p>Update to ACHex</p>



<ul class="wp-block-list">
<li>Added condensing service &#8211; heat transfer coefficient is required when this service is in use.<br>only total condensation is currently supported</li>



<li>Added support for subcooling when condensing service is in use</li>



<li>Results interface now can be maximized to fill screen</li>



<li>Added water and steam properties</li>
</ul>



<h2 class="wp-block-heading">HExS &#8211; v2.0.0.2</h2>



<p>Update to HCHex</p>



<ul class="wp-block-list">
<li>Introduced latent heat input on shell side and tube side</li>



<li>Added support for phase change.</li>



<li>Calculate both inlet flow rates when heat duty and temperatures are specified</li>
</ul>



<h2 class="wp-block-heading">HExS &#8211; v2.0.0.1</h2>



<p>Update to DHex</p>



<ul class="wp-block-list">
<li>Added use hydraulic diameter for nusselt number calculation. This feature can be accessed through the software setting screen</li>



<li>Minor fixes to interface</li>
</ul>



<h2 class="wp-block-heading">HExS &#8211; v2.0.0.0</h2>



<p>Update to S&amp;THex</p>



<ul class="wp-block-list">
<li>Update error log viewer, the software will now issue messages in the error log that<br>include the following types:<br>ERROR: This type of messages is used for errors in input or results, the software will stop until errors are fixed by the user<br>WARNING: This type of message is used for warning when parameters are exceeded, the software will continue buy some results may be invalid<br>MESSAGE: This type of message is used for general software informative messages<br>INFO: This type of message is used to provide additional information and guidance during operation<br>New Features:</li>



<li>Added kern tube counts</li>



<li>Automate multiple cases by simply setting the changing parameters and allowing the software to iterate through these parameters and generate final results.</li>



<li>Iterate through kern tube counts using the multiple cases feature</li>
</ul>



<p>Automated mode for multiple case simulation: instead of manually changing values to add a case, this mode<br>will do the exact without user intervention. The manual mode is still avialable too.<br>You can now perform a simulation study by changing any of the parameters under the Study scenarios below:<br>Study parameters 1:<br>Tube outer diameter, Tube number of passes, Tube length, Number of tubes, Baffle spacing<br>Study parameters 2:<br>Uses kern tube counts to iterated between Shell diameters to obtain the number of tubes for a given number of passes.</p>



<p>User can set the study parameters and the software will automate the calculation steps and add the final result to summary screen<br>where the changes between each can can be detected.<br>This case study mode will automate the manual input for trial and error to optimise results.</p>



<h2 class="wp-block-heading">HExS – v1.0.0.1</h2>



<p>correct a bug in warning messages for P Props physical properties database</p>



<h2 class="wp-block-heading">HExS – v1.0.0.0</h2>



<p>First public release</p>
<p>The post <a href="https://www.webbusterz.net/hexs-version-history/">HExS version history</a> appeared first on <a href="https://www.webbusterz.net">WeBBusterZ Engineering</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
