<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>double pipe heat exchanger Archives - WeBBusterZ Engineering</title>
	<atom:link href="https://www.webbusterz.net/tag/double-pipe-heat-exchanger/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.webbusterz.net/tag/double-pipe-heat-exchanger/</link>
	<description>Engineering Software Solutions</description>
	<lastBuildDate>Mon, 04 May 2026 17:18:42 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.webbusterz.net/wp-content/uploads/2017/03/cropped-wbzlogo-300x141-32x32.png</url>
	<title>double pipe heat exchanger Archives - WeBBusterZ Engineering</title>
	<link>https://www.webbusterz.net/tag/double-pipe-heat-exchanger/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>DHex version history</title>
		<link>https://www.webbusterz.net/dhex-version-history/</link>
		
		<dc:creator><![CDATA[webbusterz]]></dc:creator>
		<pubDate>Wed, 24 Jul 2019 14:06:20 +0000</pubDate>
				<category><![CDATA[Software version history]]></category>
		<category><![CDATA[double pipe heat exchanger]]></category>
		<guid isPermaLink="false">http://www.webbusterz.net/?p=613</guid>

					<description><![CDATA[<p>Below is a version history for Double Pipe Heat Exchanger Design (DHex) software: DHex v6.0.0.0 DHex v5.0.0.0 DHex v4.0.0.0 DHex v3.1.05 DHex v3.1.0.4 DHex v3.1.0.3 DHex v3.1.0.2 DHex v3.1.0.1 DHex v3.1.0.0 DHex v3.0.0.3 DHex v3.0.0.2 DHex v3.0.0.1 DHex v3.0.0.0 DHex v2.1.0.0 DHex v2.0.0.0 DHex v1.0.0</p>
<p>The post <a href="https://www.webbusterz.net/dhex-version-history/">DHex version history</a> appeared first on <a href="https://www.webbusterz.net">WeBBusterZ Engineering</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p><strong>Below is a version history for Double Pipe Heat Exchanger Design (DHex) software:</strong></p>



<h2 class="wp-block-heading">DHex v6.0.0.0</h2>



<ul class="wp-block-list">
<li>Added license tools to allow license removal for users with an active maintenance plan.</li>



<li>Added Download button in the Check for Updates window to enable automated updates to the latest version for users with an active maintenance plan.</li>



<li>Update error log viewer, the software will now issue messages in the error log that<br>include the following types:<br>ERROR: This type of messages is used for errors in input or results, the software will stop until errors are fixed by the user<br>WARNING: This type of message is used for warning when parameters are exceeded, the software will continue buy some results may be invalid<br>MESSAGE: This type of message is used for general software informative messages<br>INFO: This type of message is used to provide additional information and guidance during operation</li>



<li>Minor optimisation to code</li>
</ul>



<h2 class="wp-block-heading">DHex v5.0.0.0</h2>



<ul class="wp-block-list">
<li>Internal code refining for Heat Exchanger Suite (HExS) publish automation</li>



<li>Enhanced material thermal conductivitues database and added more material thermal conductvities.</li>



<li>Added new setting to check for software updates on start</li>



<li>Added physical properties PProps internal database containing 500 fluids</li>
</ul>



<h2 class="wp-block-heading">DHex v4.0.0.0</h2>



<ul class="wp-block-list">
<li>Maintenance release addressing software licensing on new activation server</li>
</ul>



<h2 class="wp-block-heading">DHex v3.1.05</h2>



<ul class="wp-block-list">
<li>Maintenance release</li>



<li>fixed bug to address failing to calculate the thermal capacity ratio</li>



<li>fixed bug to address failing to calculate the number of transfer unit</li>



<li>fixed bug to address failing to calculate pressure drop in annulus side</li>
</ul>



<h2 class="wp-block-heading">DHex v3.1.0.4</h2>



<ul class="wp-block-list">
<li>Maintenance release</li>
</ul>



<h2 class="wp-block-heading">DHex v3.1.0.3</h2>



<ul class="wp-block-list">
<li>Added used hydraulic diameter for Nusselt number calculation. This feature can be accessed through the software setting screen</li>



<li>Minor fixes to interface</li>
</ul>



<h2 class="wp-block-heading">DHex v3.1.0.2</h2>



<ul class="wp-block-list">
<li>Software upgrade to Microsoft dot Net 4.8 Framework</li>



<li>Fixed bug affecting retrieving film heat transfer coefficient user database entries</li>



<li>Added water and steam properties</li>



<li>Added check for software update</li>
</ul>



<h2 class="wp-block-heading">DHex v3.1.0.1</h2>



<ul class="wp-block-list">
<li>Fixed bug affecting retrieving Nusselt user correlations when user is using comma for decimal point separator</li>
</ul>



<h2 class="wp-block-heading">DHex v3.1.0.0</h2>



<ul class="wp-block-list">
<li>Maintenance release addressing software licensing on new activation server</li>



<li>Added license information screen can be accessed from Help menu</li>
</ul>



<h2 class="wp-block-heading">DHex v3.0.0.3</h2>



<ul class="wp-block-list">
<li>Maintenance release addressed software digital signature and end user license agreement</li>
</ul>



<h2 class="wp-block-heading">DHex v3.0.0.2</h2>



<ul class="wp-block-list">
<li>Ability to designate Nusselt user correlations to inner pipe or outer pipe side</li>



<li>Plot temperature profile for hot and cold sides, check temperature cross chart</li>



<li>Multi case feature will now save cases in a case list and reload a case upon request during run time.&nbsp;</li>
</ul>



<h2 class="wp-block-heading">DHex v3.0.0.1</h2>



<ul class="wp-block-list">
<li>Maintenance release</li>
</ul>



<h2 class="wp-block-heading">DHex v3.0.0.0</h2>



<ul class="wp-block-list">
<li>Software upgrade to Microsoft dot Net 4.6 Framework</li>



<li>New user interface</li>



<li>Added pumping power calculation</li>



<li>Add your own Nusselt correlations to use in software calculations</li>



<li>Added Unit converter includes 23 measurements units with 200-unit conversion</li>



<li>Added Input Consistency check – to reduce input errors related to decimal point separator</li>



<li>Some enhancement to results display</li>



<li>Added Re-Save feature faster saving for edited files</li>



<li>Added ability to enter heat transfer coefficient on both inner pipe side and outer pipe side</li>



<li>Ability to enter Heat Duty</li>



<li>Ability to calculate unknown exit temperatures on both sides or any two temperatures on both sides.</li>



<li>Ability to add multiple cases to one results grid.</li>



<li>Ability to add heat transfer coefficients in a user database table and load it during calculation.</li>



<li>Added the following Nusselt number correlations:</li>



<li>– Petukhov and Popov</li>



<li>– Sleicher and Rouse</li>



<li>– Gnielinski</li>



<li>– Prandtl</li>



<li>– Modified Dittus-Boelter</li>



<li>Pressure drop friction factor chart under finned tube option has been removed and calculation of this friction factor is now done by the software</li>



<li>Enhance summary of results presentation</li>
</ul>



<h2 class="wp-block-heading">DHex v2.1.0.0</h2>



<ul class="wp-block-list">
<li>Added Ability to export results to Engineering Datasheet format (To Microsoft Excel)</li>
</ul>



<h2 class="wp-block-heading">DHex v2.0.0.0</h2>



<ul class="wp-block-list">
<li>Enhanced User Interface</li>



<li>Added support for WeBBusterZ Physical properties database</li>



<li>Added fouling factors</li>



<li>Fixed some small programming bugs</li>
</ul>



<h2 class="wp-block-heading">DHex v1.0.0</h2>



<ul class="wp-block-list">
<li>First release </li>
</ul>
<p>The post <a href="https://www.webbusterz.net/dhex-version-history/">DHex version history</a> appeared first on <a href="https://www.webbusterz.net">WeBBusterZ Engineering</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Double pipe heat exchanger video</title>
		<link>https://www.webbusterz.net/double-pipe-heat-exchanger-video/</link>
		
		<dc:creator><![CDATA[webbusterz]]></dc:creator>
		<pubDate>Tue, 05 Feb 2019 10:58:49 +0000</pubDate>
				<category><![CDATA[Videos]]></category>
		<category><![CDATA[double pipe heat exchanger]]></category>
		<guid isPermaLink="false">http://www.webbusterz.net/?p=337</guid>

					<description><![CDATA[<p>This video clip demonstrates the feature for double pipe heat exchanger (DHex) software Software features example Oil Heat Exchanger Example General timeline: 00:00:00 Example 00:02:53 Temperature Profile 00:08:02 How to add a heat transfer coefficient correlation</p>
<p>The post <a href="https://www.webbusterz.net/double-pipe-heat-exchanger-video/">Double pipe heat exchanger video</a> appeared first on <a href="https://www.webbusterz.net">WeBBusterZ Engineering</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>This video clip demonstrates the feature for double pipe heat exchanger (DHex) software</p>



<p><span style="color: #0000ff;"><strong>Software features example</strong></span></p>



<figure class="wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe title="Double Pipe Heat Exchanger Software (DHex) v5.0 — New Features &amp; Improvements Demonestration" width="790" height="444" src="https://www.youtube.com/embed/aJzHv_Y1Y_g?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe>
</div></figure>



<p><span style="color: #0000ff;"><strong>Oil Heat Exchanger Example</strong></span></p>



<p>General timeline:<br>
00:00:00 Example<br>
00:02:53 Temperature Profile<br>
00:08:02 How to add a heat transfer coefficient correlation</p>



<figure class="wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe title="Double pipe heat exchanger design v3.0 - Example oil exchanger" width="790" height="444" src="https://www.youtube.com/embed/FQxHImSQyZ0?feature=oembed" frameborder="0" allow="accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture" allowfullscreen></iframe>
</div></figure>
<p>The post <a href="https://www.webbusterz.net/double-pipe-heat-exchanger-video/">Double pipe heat exchanger video</a> appeared first on <a href="https://www.webbusterz.net">WeBBusterZ Engineering</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
